Calculate savings from a more efficient furnace by comparing the fuel needed to deliver the same useful heat at the old and new seasonal efficiencies. Apply the same variable fuel price to both cases, then evaluate electricity, maintenance, installation cost, and fixed charges separately.
Open the Furnace Savings Calculator.
How to Calculate Savings from a More Efficient Furnace
A furnace efficiency improvement reduces fuel required for a given useful heating demand. The useful heat requirement should remain the same in a fair equipment comparison.
The basic relationship is:
Fuel required = useful heating demand/seasonal efficiency as a decimal
For natural gas, divide fuel BTU by 100,000 to obtain therms. Multiply therms by the applicable variable price per therm.
Annual fuel-cost savings are old modeled fuel cost minus new modeled fuel cost. A positive result means lower modeled fuel cost under the stated assumptions.
The calculator above uses useful annual heating load in million BTU, current and new AFUE, fuel price, and a climate multiplier. Use Moderate, with factor 1.00, when the annual load already represents the actual climate assumption.
Carrier’s AFUE explanation describes the rating as seasonal fuel conversion rather than a promise for every operating instant. Use compatible seasonal assumptions when estimating annual savings.
Establish the Heating Portion of Fuel Use
Utility gas use can include water heating, cooking, drying, fireplaces, and other appliances. A furnace upgrade does not automatically reduce those loads.
If beginning with annual gas bills, separate space-heating consumption as reasonably as the data allow. A warm-weather baseline can help, but changing occupancy or water use can make it imperfect.
Fixed account charges should not be treated as fuel savings unless the project actually eliminates them. Replacing a gas furnace with another gas furnace usually leaves the gas service in place.
Use a consistent billing period and weather basis. Comparing an unusually mild year with a colder year can obscure equipment performance.
If useful annual heat is estimated from old furnace fuel, multiply the heating fuel energy by the appropriate old seasonal efficiency. Do not enter the old fuel energy directly as useful load and divide by efficiency again.
Record whether the heating requirement comes from a building energy model, normalized bills, or a simpler planning assumption. The confidence of the savings estimate depends strongly on that starting point.
Work an 80-Million-BTU Example
Assume an illustrative useful annual heating requirement of 80 million BTU. Compare a 78% AFUE furnace with a 95% AFUE furnace at a hypothetical variable gas price of $1.50 per therm.
Old fuel requirement is:
80,000,000/0.78 = 102,564,103 BTU
That is approximately 1,025.64 therms.
New fuel requirement is:
80,000,000/0.95 = 84,210,526 BTU
That is approximately 842.11 therms.
Fuel savings are approximately 183.54 therms. At $1.50 per therm, annual variable fuel-cost savings are:
183.54 ×$1.50 ≈$275.30
Enter 80,78,95,1.50, and Moderate in the calculator to reproduce the comparison.
| Annual useful heating | Old 78% fuel use | New 95% fuel use | Savings at $1.50/therm |
|---|---|---|---|
| 40 million BTU | 512.82 therms | 421.05 therms | $137.65 |
| 60 million BTU | 769.23 therms | 631.58 therms | $206.48 |
| 80 million BTU | 1,025.64 therms | 842.11 therms | $275.30 |
| 100 million BTU | 1,282.05 therms | 1,052.63 therms | $344.13 |
The prices and loads are illustrative. They are not current tariff quotes or typical requirements for every home.
Use the Efficiency Ratio for a Bill-Based Cross-Check
When the old space-heating fuel quantity is already known, the equal-heat shortcut is:
New heating fuel = old heating fuel × old efficiency/new efficiency
If the old furnace uses 900 therms specifically for space heating, the new modeled quantity is:
900 × 0.78/0.95 ≈738.95 therms
The reduction is approximately 161.05 therms, or 17.89% of the old heating fuel.
An AFUE increase from 78% to 95% is 17 percentage points. The percentage fuel reduction is different because fuel demand changes inversely with efficiency.
If the 900 therms includes 200 therms of nonheating gas, apply the ratio only to the 700 heating therms. New modeled heating use becomes approximately 574.74 therms, and total use becomes 774.74 therms after adding the unchanged 200.
That case saves 125.26 therms, not 161.05. Isolating the heating boundary prevents the calculation from claiming savings on a water heater or other unchanged appliance.
Keep Fuel Units and Prices Compatible
A therm measures 100,000 BTU of energy. Gas volume units require a heat-content conversion before applying an energy-based comparison.
EIA’s natural gas unit guidance explains that gas heat content varies and that bills may provide the supplier’s conversion.
Do not treat oneCcf as exactly one therm unless the supplier’s billing basis supports that approximation. Ccf is one hundred cubic feet, while therms measure energy.
Use the variable price attributable to another unit of consumption. Dividing a small monthly bill including fixed charges by therms can overstate the marginal savings rate.
If the tariff has tiers or time-dependent elements, evaluate the relevant consumption blocks rather than applying a simple average indiscriminately.
Fuel price sensitivity can be shown without pretending to forecast prices. The 183.54-therm example saves about $183.54 at $1.00 per therm and $458.84 at $2.50 per therm.
Interpret the Calculator’s Climate Multiplier
The climate selection multiplies the entered annual load for both furnaces. It is a scenario adjustment, not an additional physical efficiency.
For the 80-million-BTU example, Cold factor 1.20 represents 96 million BTU of useful demand. Modeled fuel savings and costs therefore rise 20% relative to the Moderate case.
If the 80 million already came from a cold-climate annual model, applying the Cold factor again double adjusts the demand.
Use factor 1.00 for a known climate-specific load. Use another factor only when intentionally describing a different useful-load scenario, and report the adjusted load explicitly.
A peak heating load in BTU/h is not the same as annual useful energy in million BTU. Do not enter a 50,000 BTU/h design rate as 50 million BTU per year without an independent seasonal-energy model.
The building’s annual demand and its equipment capacity answer different questions. A savings calculator does not select the replacement furnace size.
Add Electricity and Other Operating Differences Separately
AFUE does not capture every operating expense. The circulation blower, inducer, controls, condensate pump, and other electrical components can change electricity consumption.
Natural Resources Canada’s furnace-label guide identifies AFUE as a fuel measure that excludes electrical use for fans, pumps, and controls.
For an illustrative additional electricity saving of 150 kWh at $0.20/kWh, add $30 to the modeled annual benefit. If electricity instead increases by 150 kWh, subtract $30.
Use matched operating evidence for that adjustment rather than assuming every higher-AFUE furnace has lower electrical demand.
Maintenance, service plans, and repair expectations also need a documented basis. Do not add a generic annual saving merely to make an upgrade’s economics look favorable.
A replacement that changes thermostat settings, heated area, or comfort expectations should be modeled with those changed services visible. Otherwise the apparent equipment saving can be confounded by changed use.
Calculate Incremental Payback Only with Positive Benefit
For an efficiency upgrade, compare the additional installed cost over the relevant alternative. The entire replacement price may include work required even for a lower-efficiency option.
Suppose the more efficient option costs an illustrative $2,000 extra after any applicable confirmed incentives. Using $275.30 annual fuel savings, simple payback is approximately 7.26 years.
If the net annual benefit falls to $150 because of different fuel prices or operating expenses, the same incremental cost gives 13.33 years.
If the net benefit is zero or negative, there is no positive simple savings payback under that scenario. Do not report a negative year count as a fast return.
Simple payback omits financing, discount rates, future prices, service life, maintenance uncertainty, and nonfinancial benefits. Use it as one comparison measure rather than a complete investment valuation.
Compare Quotes and Check Results After Installation
Ask each proposal to state furnace AFUE, useful output, load-calculation basis, blower requirements, installation work, and the scope of venting, drainage, or electrical changes.
A higher-efficiency model should still be correctly sized and installed. Oversizing, restrictive ducts, and poor controls can affect comfort and operation even when the certified AFUE is high.
After installation, compare weather-adjusted heating fuel over suitable periods and retain changes in occupancy or thermostat use. One lower bill in a warmer month does not establish the annual saving.
Keep the original heating fuel, useful-load estimate, efficiency assumptions, tariff, and incremental-cost comparison together. That record makes the savings calculation reviewable and easy to revise when prices or building conditions change.