Range Hood CFM Calculator
Calculate an HVI residential canopy-hood width reference for wall or island locations. Appliance requirements, capture geometry, fan pressure capability and makeup air remain separate.
Calculate an HVI residential canopy-hood width reference for wall or island locations. Appliance requirements, capture geometry, fan pressure capability and makeup air remain separate.
Calculate an HVI residential canopy-hood width reference for wall or island locations. Appliance requirements, capture geometry, fan pressure capability and makeup air remain separate.
Compare window AC cooling ratings, room-load scenarios, efficiency metrics and portable rating differences on a consistent basis.
Estimate the recommended bathroom exhaust fan capacity in CFM based on room dimensions, ceiling height, and how many times per hour you want the air exchanged.
Estimate central AC capacity with a transparent planning example and distinguish whole-home loads, nominal tons and equipment selection.
Estimate the required exhaust fan airflow in CFM based on room dimensions, desired air changes per hour, and ventilation effectiveness.
Convert cooling BTU/h to tons while preserving rating conditions, capacity ranges and the distinction between output and electrical input.
Convert a cooling load from BTU/h to tons and understand the separate checks needed for equipment selection.
Calculate CFM from mean velocity and matching area, with rectangular and round duct examples and measurement pitfalls.
Estimate residential kitchen hood airflow with width-based examples, capture considerations, duct performance and replacement-air planning.
Calculate required airflow in CFM based on floor area, ceiling height, desired air changes per hour, occupancy load, and ventilation intensity factor.
Estimate lateral duct-wrap area for a straight round or rectangular run, using outside dimensions and an explicitly chosen extra-material allowance.
Calculate the recommended airflow in CFM for a room based on room dimensions, ceiling height, and desired air changes per hour.
Calculate volumetric airflow from representative mean velocity and the matching clear flow cross-sectional area.
Estimate bathroom exhaust CFM with a checked volume example, compare HVI guidance, and review duct resistance, controls, replacement air, and measured delivery.
Estimate cooling airflow from a matched sensible capacity and explicit supply-to-room temperature difference.
Calculate target airflow from an explicitly selected room/house volume and air-change rate. Actual fan performance and the suitability of the target are separate.
Calculate cooling airflow from matched sensible capacity and temperature difference, with checked SHR, density, equipment, and duct-boundary examples.
Calculate the true length of a duct offset using rise, run, number of elbows, and fitting angle multiplier. Useful for estimating material length needed for an offset section in HVAC ductwork.
Calculate ACH from CFM and matching room volume, with checked examples for flow categories, intermittent operation, clean-air equivalents, and uncertainty.
Estimate the maximum equivalent duct length allowed for a ventilation run based on fan rated maximum equivalent length, duct diameter, number of elbows, and wall cap type. The result reflects a common equivalent-length approach where fittings and smaller duct sizes reduce the straight duct length available.
Estimate an ideal round branch diameter from design airflow and an explicitly selected velocity target. This is an area/velocity calculation, not a full friction design.
Estimate daily heat pump kWh from useful heat and matched COP, with checked operating profiles, auxiliary heat, weather-factor, and metered-power examples.
Estimate ground source heat pump capacity with checked building, ground-extraction, seasonal-balance, and fluid-flow examples while separating loop design.
Estimate house HVAC size with a checked planning example, then compare separate loads, matched equipment output, modulation, and room distribution.
Estimate the recommended rectangular HVAC trunk duct size based on total airflow, target friction rate, duct aspect ratio, and design velocity. This calculator helps size a main supply trunk by calculating the required duct cross-sectional area and resulting equivalent trunk width for a chosen height-to-width ratio.
Measure HVAC supply and return temperature differences with matched locations, checked cooling and heating examples, airflow context, and uncertainty limits.
Calculate refrigerant superheat from matched vapor and dew temperatures, with checked correction, glide, unit-conversion, and uncertainty examples.
Estimate annual HVAC electricity from nonoverlapping operating periods, with checked full-year, active-runtime, fuel-boundary, and tariff examples.
Calculate EER from matched cooling output and electrical watts, with checked fan accounting, COP conversion, rating distinctions, and energy examples.