HVAC Runtime Calculator
Estimate daily HVAC runtime based on system capacity, average electrical draw, thermostat setpoint difference, outdoor climate severity, and home insulation quality.
Estimate daily HVAC runtime based on system capacity, average electrical draw, thermostat setpoint difference, outdoor climate severity, and home insulation quality.
Estimate seasonal heating output and electricity use for a heat pump using HSPF, heating capacity, runtime, and electricity rate. HSPF is the total seasonal heating output in BTU divided by total electricity input in watt-hours.
Calculate electrical energy from measured average electrical power and the duration of the same interval.
Estimate HVAC duty cycle as the percentage of time a heating or cooling system runs during an observation period based on total runtime and cycle behavior.
Calculate the temperature difference between a corrected suction-line measurement and the appropriate corrected dew saturation reference at the matched pressure.
Calculate the signed liquid-reference subcooling temperature difference from matched saturation and liquid-line temperatures, with optional known signed calibration corrections.
Calculate either superheat or subcooling from measured refrigerant temperatures and pressures. Enter the saturated temperature corresponding to the measured pressure along with the actual line temperature to find the temperature difference.
Subtract matched representative air temperatures in the selected operating-mode direction.
Calculate the sensible heat ratio (SHR) for an HVAC process using sensible cooling load and latent cooling load. SHR indicates the fraction of total cooling devoted to sensible heat removal.
Estimate moist-air specific enthalpy on a dry-air mass basis from 32 to 122 F using relative humidity and an altitude-based standard-atmosphere pressure estimate.
Calculate the coefficient of performance for heating or cooling output and electrical input on a consistent measurement boundary.
Estimate HVAC system efficiency using cooling output, electrical power use, seasonal runtime, climate factor, and system age. This calculator approximates effective seasonal efficiency as adjusted BTU output per watt-hour consumed.
Calculate the Energy Efficiency Ratio (EER) of an air conditioner or cooling system using cooling capacity and electrical power input. EER equals cooling output in BTU per hour divided by power input in watts.
Illustrative annual variable cooling-charge comparison using compatible SEER2 values and a common seasonal cooling-energy basis expressed as capacity times equivalent full-load hours.
Estimate an air conditioner’s SEER rating from cooling output and electricity use, and compare annual operating cost based on local usage and electricity price.
Estimate annual cooling cost savings when upgrading from an existing air conditioner to a higher-SEER system based on capacity, runtime, electricity rate, and system efficiency.
Compare annual HVAC operating-cost scenarios from explicitly established annual energy quantities, compatible variable rates and separate maintenance/other included costs.
Calculate a variable electricity charge from explicitly measured or established electrical kWh and the matching rate.
Calculate period HVAC electricity from matched average electrical input and observation time. Sum nonoverlapping heating, cooling, fan-only and standby periods for an annual estimate.
Estimate variable energy-charge savings for the same useful HVAC service using compatible old and new dimensionless efficiency or COP ratios.
Estimate the required fresh air ventilation rate in CFM based on floor area, ceiling height, target air changes per hour, number of occupants, and activity level.
Calculate the airflow required for a stated room volume and explicitly selected air-change target. Actual fan operating performance and pressure selection are separate.
Calculate air changes per hour (ACH) using room dimensions and airflow. ACH estimates how many times the total air volume in a room is replaced each hour.
Estimate register airflow from representative mean velocity and an effective area defined on the same instrument or manufacturer basis.
Convert an explicitly chosen attic air-exchange assumption into an airflow reference from attic volume.
Calculate target airflow from an explicitly selected room/house volume and air-change rate. Actual fan performance and the suitability of the target are separate.
Calculate an HVI residential canopy-hood width reference for wall or island locations. Appliance requirements, capture geometry, fan pressure capability and makeup air remain separate.
Calculate an HVI residential canopy-hood width reference for wall or island locations. Appliance requirements, capture geometry, fan pressure capability and makeup air remain separate.
Estimate the recommended bathroom exhaust fan capacity in CFM based on room dimensions, ceiling height, and how many times per hour you want the air exchanged.
Estimate the required exhaust fan airflow in CFM based on room dimensions, desired air changes per hour, and ventilation effectiveness.