Heat Pump Operating Cost Calculator

Heat Pump Operating Cost Calculator

Estimate a defined winter-period variable electricity charge from matched heat-pump output/COP and separately entered backup electrical operation.
Variable electricity charge for the stated period:
Support this tool
Buy us a coffee
If this Heat Pump Operating Cost Calculator helped you, you can support the site with a small donation. It keeps the tools on the site free and supports ongoing improvements.
Buy us a coffee
Secure donation via Gumroad

What this calculator measures

Estimate a defined winter-period variable electricity charge from matched heat-pump output/COP and separately entered backup electrical operation.

Inputs and units

Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.

Input Example value or available basis
Heat Pump Heating Output During the Stated Hours (thermal kW) 9
Compatible COP Excluding Separately Entered Backup 3
Matching Heat Pump Hours per Day 8
Separately Counted Backup Electrical Input (kW) 2
Backup Hours per Day on the Same Period 1
Period Length (days) 30
Illustrative or Documented Variable Electricity Rate ($/kWh) 0.16

Calculation method

Divide matched useful heat output by COP to obtain electrical input during the corresponding hours.

Add separately counted backup kW times its own hours, multiply by period days and the variable electricity rate.

For changing weather or operating points, calculate separate bins with matched inputs and sum charges; do not apply another climate factor to an already matched ratio.

Worked example

9 thermal kW at COP 3 for 8 h/day plus 2 kW backup for 1 h/day over 30 days uses 780 kWh and costs $124.80 at an illustrative $0.16/kWh.

How to use the result

Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.

Limits and checks

Do not add backup already included in a measured whole-system COP or electrical total.

These hours must match the stated output and COP; thermostat-enabled time is not automatically full-output time.

The tool does not predict defrost, weather-bin hours, capacity limits, demand charges or a complete utility bill.

An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.