Heat Pump Savings Calculator

Heat Pump Savings Calculator

Compare variable heating electricity charges for the same useful seasonal heat using explicitly supplied compatible old and new seasonal average COP values.
Modeled variable heating-charge savings (negative means increase):
Support this tool
Buy us a coffee
If this Heat Pump Savings Calculator helped you, you can support the site with a small donation. It keeps the tools on the site free and supports ongoing improvements.
Buy us a coffee
Secure donation via Gumroad

What this calculator measures

Compare variable heating electricity charges for the same useful seasonal heat using explicitly supplied compatible old and new seasonal average COP values.

Inputs and units

Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.

Input Example value or available basis
Same Useful Seasonal Heating Energy (thermal kWh) 18000
Old System Compatible Seasonal Average COP 2.5
New System Compatible Seasonal Average COP 3.5
Same Variable Electricity Rate ($/kWh) 0.16

Calculation method

Calculate old electrical kWh as useful thermal kWh divided by the old compatible seasonal COP and do the same for the new COP.

Multiply their difference by the same variable electricity rate.

Keep capital costs, confirmed one-time rebates, maintenance and other ownership terms outside recurring electricity savings.

Worked example

18,000 thermal kWh at old COP 2.5 uses 7,200 electrical kWh; at new COP 3.5 it uses about 5,142.857 kWh. At an illustrative $0.16/kWh, savings are about $329.14.

How to use the result

Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.

Limits and checks

Both COP values must use the same delivered-heat, fans/pumps and backup boundary over comparable seasonal conditions.

The tool does not predict COP from climate, equipment age or a single favorable operating point.

Negative savings are a valid modeled cost increase. No payback, incentive eligibility or purchase recommendation is implied.

An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.