Heat Pump Efficiency Calculator

Heat Pump Efficiency Calculator

Calculate heating COP for one matched operating condition. Compare temperatures by entering independently measured or published matched data for each condition.
Heating COP on the defined boundary:
Support this tool
Buy us a coffee
If this Heat Pump Efficiency Calculator helped you, you can support the site with a small donation. It keeps the tools on the site free and supports ongoing improvements.
Buy us a coffee
Secure donation via Gumroad

What this calculator measures

Calculate heating COP for one matched operating condition. Compare temperatures by entering independently measured or published matched data for each condition.

Inputs and units

Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.

Input Example value or available basis
Heating Output at the Stated Condition (kW) 10
Matched Total Electrical Input (kW) 3

Calculation method

Divide matched thermal output by electrical input at each operating condition.

Record indoor and outdoor temperatures with the source data, then repeat the calculation for another condition. Temperature affects real performance; it does not supply a universal correction to an already matched ratio.

Worked example

At 7 C outdoors, 10 kW heating output and 2.5 kW electrical input give COP 4. At -7 C, independently stated 7.5 kW output and 3 kW input give COP 2.5.

How to use the result

Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.

Limits and checks

This tool does not extrapolate performance to another temperature, source type, compressor speed or defrost condition.

Use the same included fans, pumps and auxiliary-heating boundary for each comparison.

Zero electrical input is invalid. A point ratio is not a seasonal performance factor.

An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.