Ductless Mini Split Size Calculator
What this calculator measures
Compare published cooling output capacity with an independently calculated design load at matching conditions.
Inputs and units
Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.
| Input | Example value or available basis |
|---|---|
| Independently Calculated Cooling Design Load (BTU/h) | 30000 |
| Published Cooling Output at Matching Design Conditions (BTU/h) | 36000 |
Calculation method
Compare published cooling output capacity with an independently calculated design load at matching conditions.
Capacity-to-load percentage equals 100 times the published output capacity divided by the supplied design load. This arithmetic does not calculate the load or establish a permitted sizing margin.
Worked example
An independently calculated 30000 BTU/h design load and a matching-condition published output capacity of 36000 BTU/h give 120 percent. The numerical difference is 6000 BTU/h, subject to separate equipment-selection review.
How to use the result
Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.
Limits and checks
Use a proper residential load calculation and actual manufacturer performance data. Neither input is inferred from square footage, climate labels, nominal tonnage, or AFUE.
A ratio at or above 100 percent does not prove that equipment is suitable. Review applicable sizing limits, operating range, distribution, and equipment-specific performance. For cooling, sensible and latent requirements must also be satisfied.
An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.