Mini Split Energy Cost Calculator
What this calculator measures
Compare heating and cooling variable electricity charges using separate useful thermal energies and compatible period COP values.
Inputs and units
Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.
| Input | Example value or available basis |
|---|---|
| Useful Heating Energy in the Compared Period (thermal kWh) | 6000 |
| Compatible Period Heating COP | 3 |
| Heat Removed in the Compared Period (thermal kWh) | 2000 |
| Compatible Period Cooling COP | 4 |
| Variable Electricity Rate ($/kWh) | 0.18 |
| Charge to Display | Heating ($); Cooling ($); Combined ($) |
Calculation method
Divide each mode thermal kWh by its compatible period COP to obtain electrical kWh, then multiply by the rate.
Compare modes over a declared period and equal component boundaries; select heating, cooling or combined charge.
Worked example
6,000 thermal kWh heating at COP 3 uses 2,000 electrical kWh; 2,000 thermal kWh cooling at COP 4 uses 500 electrical kWh. At $0.18/kWh, charges are $360 heating, $90 cooling and $450 combined.
How to use the result
Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.
Limits and checks
The tool does not predict seasonal COP from nameplate ratings or climate.
SEER2 and HSPF2 use different seasonal procedures and must not be entered directly as dimensionless COP.
Include backup, fans and standby exactly once on a consistent system boundary.
An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.