Greenhouse BTU Calculator
What this calculator measures
Estimate nighttime greenhouse covering heat loss plus separately established additional losses from explicit area, U-factor and indoor/outdoor temperatures.
Inputs and units
Keep all entries on the measurement boundary and unit convention stated below. Example values are editable calculation inputs, not specifications for your equipment or a particular production job.
| Input | Example value or available basis |
|---|---|
| Exposed Covering Area Excluding Ground (sq ft) | 800 |
| Covering Overall U-Factor (BTU/h sq ft F) | 0.85 |
| Night Indoor Design Temperature (F) | 65 |
| Night Outdoor Design Temperature (F) | 20 |
| Additional Losses Excluding Covering Term (BTU/h) | 2000 |
Calculation method
Multiply actual exposed covering area by its suitable overall U-factor and the positive indoor-minus-outdoor design temperature difference.
Add only independently established losses not already included, such as compatible infiltration, ventilation or ground/perimeter terms.
For mixed materials, use the sum of each area times U-factor rather than an unweighted average.
Worked example
800 sq ft of covering at U 0.85 and a 45 F design difference loses 30,600 BTU/h. An independently estimated 2,000 BTU/h of other losses gives 32,600 BTU/h.
How to use the result
Select the output quantity you need, enter compatible values, and compare the result with the independently worked example. Where the form offers several output choices, read the units in that choice; different physical quantities must not be combined into one total.
Limits and checks
This steady nighttime loss model does not credit daytime solar gains or stored heat and does not guarantee crop protection.
U-factors must match covering construction, installation and relevant conditions; do not add a separate radiation or leakage term already included in an empirical factor.
Additional losses must be independently estimated; floor/ground area is not automatically exposed glazing area.
Result is useful thermal heating output, not heater fuel input or a complete combustion/electrical installation design.
An undefined or out-of-domain combination produces a calculation-failure message. Check the positive denominators, stated input ranges, and any required matching basis before changing the calculation inputs.